The heat transfer coefficient α, usually written h in English literature, states how much heat is transferred per square metre of surface and per kelvin of temperature difference between a wall and a flowing fluid. Its unit is W/(m²·K). Unlike thermal conductivity, it is not a material property: it depends on the fluid, the flow velocity and the geometry, and ranges from a few W/(m²·K) in still air to more than 10,000 W/(m²·K) for water in narrow channels.
The convective heat transfer coefficient α (or h) is the proportionality factor between the heat flux at a surface and the temperature difference between that surface and the fluid. A value of 1,000 W/(m²·K) means that every square metre transfers 1,000 W per kelvin of temperature difference.
You know α, for example from the table below or from a simulation, and want the transferred heat flow and the convective thermal resistance.
The convective heat flow between a surface and a fluid is described by Newton's law of cooling. α combines all influences of the flow into a single number.
Q̇ = α · A · (T_s − T_f) Rth = 1 / (α · A) Rearranged, this gives the convective thermal resistance in K/W. It slots directly into the series chain of thermal resistances from the semiconductor to the coolant.
Calculate thermal resistance →The three quantities are often confused, but they describe different things. λ belongs to the material, α to the interface between wall and fluid, and U to the whole component from fluid to fluid.
| Quantity | Unit | Describes | Depends on |
|---|---|---|---|
| Thermal conductivity λ (k) | W/(m·K) | Heat conduction inside a material | Material and temperature |
| Heat transfer coefficient α (h) | W/(m²·K) | Heat transfer between a surface and a flowing fluid (convection) | Fluid, velocity, flow regime, geometry |
| Overall heat transfer coefficient U | W/(m²·K) | Total heat transfer through a wall from one fluid to the other | Both convective coefficients, wall thickness and wall conductivity |
1/U = 1/α₁ + s/λ + 1/α₂ For a plane wall, three partial resistances add up: convection on one side, conduction through the wall of thickness s and convection on the other side. The smallest α dominates, so improving the weaker side almost always pays off first.
More on thermal conductivity λ →The values show orders of magnitude. Where a specific case falls depends on velocity, geometry and temperature. For an actual design there is no way around a calculation via the Nusselt number, a simulation or a measurement.
| Application | α in W/(m²·K) | Note |
|---|---|---|
| Natural convection, air and gases | 2 to 25 | Passive heat sinks and enclosure surfaces without a fan. |
| Forced convection, air and gases | 25 to 250 | Fan-cooled heat sinks. In fin channels at a few m/s, values are usually around 30 to 100. |
| Natural convection, water and other liquids | 50 to 1,000 | Stagnant liquid, for example a tank or bath without circulation. |
| Forced convection, water and water-glycol in channels | 100 to 20,000 | Liquid cold plates. With channels of a few millimetres at around 1 m/s, typically several thousand. Water-glycol is clearly lower than water. |
| Microchannels with water (Dh below 1 mm) | about 5,000 to 25,000 | Estimated from Nu ≈ 4 to 8 at Dh = 0.2 to 0.5 mm. High pressure drop. |
| Boiling and condensation (phase change) | 2,500 to 100,000 | Two-phase cooling as well as evaporation and condensation inside heat pipes and vapor chambers. |
Ranges according to Incropera, Fundamentals of Heat and Mass Transfer (Table 1.1), and the VDI Heat Atlas. Values for fin channels and microchannels are estimated with the Nusselt correlations on this page.
Water transfers heat at a surface orders of magnitude better than air. The reasons are its roughly 23 times higher thermal conductivity and its roughly 17 times lower kinematic viscosity, which gives a higher Reynolds number at the same velocity. Two examples for a 100 mm long flat plate in parallel flow, calculated with the tool above:
α cannot simply be looked up; it is determined via dimensionless numbers. The Nusselt number is the dimensionless heat transfer coefficient. Empirical correlations give Nu as a function of the Reynolds and Prandtl numbers, and α follows from Nu.
Nu = α · L / λ ⇒ α = Nu · λ / L Nusselt number: ratio of convective to purely conductive heat transfer in the fluid. L is the characteristic length, i.e. the plate length or the hydraulic diameter Dh. λ is the thermal conductivity of the fluid, not of the wall.
Re = v · L / ν Reynolds number: ratio of inertial to viscous forces. It decides whether the flow is laminar or turbulent. In tubes and channels, flow below Re ≈ 2,300 is considered laminar; on a flat plate transition occurs around Re ≈ 5 · 10⁵.
Pr = ν / a = μ · c_p / λ Prandtl number: a pure fluid property, the ratio of momentum diffusivity to thermal diffusivity. Air ≈ 0.7, water at 25 °C ≈ 6, water-glycol 50/50 ≈ 30, oils well above 100.
Dh = 4 · A / P Hydraulic diameter for non-circular cross sections: four times the cross-sectional area A divided by the wetted perimeter P. For a tube Dh equals the inner diameter, for a flat gap it is roughly twice the gap width.
The following equations are standard forced-convection correlations from Incropera and the VDI Heat Atlas. Fluid properties are evaluated at the film temperature for plates and at the mean fluid temperature for channels. The calculator above uses exactly these equations.
Flat plate, laminar (average Nu over length L)
Nu = 0.664 · Re^0.5 · Pr^(1/3) Re < 5 · 10⁵, Pr ≥ 0.6, isothermal plate.
Flat plate, turbulent
Nu = 0.037 · Re^0.8 · Pr^(1/3) 5 · 10⁵ < Re < 10⁸, 0.6 < Pr < 60. Applies to a boundary layer that is turbulent from the leading edge. With a laminar leading section, 871 is subtracted: Nu = (0.037 · Re^0.8 − 871) · Pr^(1/3).
Channel or tube, laminar, fully developed
Nu = 3.66 (constant wall temperature) or Nu = 4.36 (constant heat flux) Re < 2,300, round tube. Square duct 2.98 or 3.61, flat gap heated on both sides 7.54 or 8.23. In the thermal entry region Nu is higher.
Tube, turbulent: Dittus-Boelter
Nu = 0.023 · Re^0.8 · Pr^0.4 Re > 10,000, 0.6 < Pr < 160, L/D > 10, fluid being heated (exponent 0.3 when cooled). Deviations of up to about 25 % are possible.
Tube, transition and turbulent: Gnielinski
Nu = (f/8) · (Re − 1000) · Pr / [1 + 12.7 · (f/8)^0.5 · (Pr^(2/3) − 1)] with f = (0.790 · ln Re − 1.64)^(−2) 3,000 < Re < 5 · 10⁶, 0.5 < Pr < 2,000. More accurate than Dittus-Boelter and also applicable in the transition region.
Between Re ≈ 2,300 and 10,000, channel flow is in the transition region. Whether it stays laminar or becomes turbulent depends on the inlet, bends and roughness, and results are much less certain. For a robust design, avoid this range or calculate both limiting cases.
Water at 25 °C flows through a cold plate with a pressed-in tube. The tube has an 8 mm inner diameter and the mean velocity is 1.5 m/s (about 4.5 l/min). The wetted inner surface of the tube is 150 cm². We want α, the convective thermal resistance and the heat flow at a 10 K difference between tube wall and water.
Water properties at 25 °C: λ = 0.607 W/(m·K), ν = 0.893 mm²/s, Pr = 6.1 Re = v · D / ν = 1.5 · 0.008 / (0.893 · 10⁻⁶) ≈ 13,440 → turbulent Nu = 0.023 · 13,440^0.8 · 6.1^0.4 ≈ 95.2 α = Nu · λ / D = 95.2 · 0.607 / 0.008 ≈ 7,220 W/(m²·K) Rth = 1 / (α · A) = 1 / (7,220 · 0.015) ≈ 0.0092 K/W Q̇ = α · A · ΔT = 7,220 · 0.015 · 10 ≈ 1,080 W The convective resistance is about 0.009 K/W. Gnielinski gives Nu ≈ 98.7 and α ≈ 7,490 W/(m²·K) for the same case, just under 4 % more. In a real cold plate the effective area is smaller because heat does not arrive evenly around the whole tube circumference. Heat spreading in the base plate and the interface between tube and plate therefore belong in the calculation too.
For a design, the product α · A is what counts. There are two levers: more surface area or a higher heat transfer coefficient. Both come at a price.
A high heat transfer coefficient alone does not make good cooling. COOLTEC designs heat sinks and liquid coolers so that heat transfer, pressure drop and installation space fit together, free and without obligation.