Internally Structured Cooling Plates
Liquid coolers with milled or inserted channel or pin structures. (...)
Rising power density makes heat dissipation the decisive factor. This guide shows when air cooling is enough, when liquid cooling becomes necessary, and how to size the right cooling solution for your power electronics.
Wherever electrical energy turns into heat, that heat has to be removed reliably. Operating temperature directly affects service life: as a rule of thumb, a rise of just 10 Kelvin already halves a component's expected lifetime.
Modern systems with high power density quickly reach the limits of natural convection. If the heat stays in the component, performance and reliability drop, and in the worst case the system fails. A well-sized electronics cooling solution keeps the junction temperature safely below the limit.
Electronics cooling is the targeted removal of a component's power dissipation to a coolant so the junction temperature stays below the permitted limit. Depending on power dissipation and available space, air-cooled heat sinks or liquid coolers are used.
The right cooling technique depends mainly on power dissipation, power density and available space. The following guidance helps with the first decision.
Air cooling suits you when
Liquid cooling pays off when
Passive air cooling
Heat sinks release heat without a fan, through natural convection and radiation. Suitable for low to medium power dissipation with enough space.
Forced air cooling
Fans or blowers actively move air across the heat sink. This lowers the thermal resistance significantly and reaches higher power dissipation, for example with bonded-fin or pin-fin heat sinks.
Liquid cooling
Cold plates with flow channels transport heat far more effectively than air. The first choice for high power density, tight space and a low target thermal resistance.
Power semiconductors such as IGBTs, MOSFETs or SiC devices produce high power dissipation on a very small area. To keep the junction temperature in the safe range, the total thermal resistance from junction to coolant must be small enough. At high power dissipation, there is usually no way around liquid cooling.
Example from practice
An IGBT dissipating 2000 W over 0.03 m², with a maximum component temperature of 70 °C and 20 °C ambient, gives a required thermal resistance of about 0.025 K/W. This value can no longer be reached with air cooling. A liquid cooling solution with a cold plate is required here.
A few parameters are enough to estimate the right cooling. Our free calculators walk you through the key steps.
Does your power electronics need the right cooling?
Our thermal experts size the cooling solution to your power dissipation, your space and your coolant.
Requirements for cooling capacity, space and materials differ by application. A selection of typical fields:
From first estimate to finished cooler: our engineers size air and liquid coolers to match your application.
Learn how to optimize cooling for high-tech applications – with solutions that are efficient, reliable, and ready to implement.
Download report